{"product_id":"klein-tools-ir1kit-digital-infrared-thermometer-10-to-1-laser-temperature-gun-with-rt210-gfci-receptacle-outlet-tester-electrical-diagnostic-safety-kit","title":"Klein Tools Electrical Tester IR1KIT Infrared Laser Thermometer (10 to 1 Spot Ratio 752F RT210 GFCI Outlet Diagnostics Thermal Scanner Pouch Set)","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333333; line-height: 1.6;\"\u003e\n\u003ch2 style=\"color: #004b87;\"\u003e\u003ca title=\"Link to Klein Tools homepage\" href=\"https:\/\/www.1toptools.com\/pages\/klein-tools\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"Klein promotional logo logout\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2274\/5945\/files\/KleinStacked-Black.png?v=1774018194\"\u003e\u003c\/a\u003e\u003c\/h2\u003e\n\u003cdiv style=\"font-family: sans-serif; color: #333; line-height: 1.6;\"\u003e\n\u003ch2 style=\"color: #004b87;\"\u003eIsolate Subsurface Breaker Overheating And Expose Receptacle Wiring Defects Instantly With Dual Technology Laser Pyrometry And Socket Interrogation Logic\u003c\/h2\u003e\n\u003cp\u003eShop the Klein Tools IR1KIT electrical diagnostic safety kit featuring a non-contact infrared laser thermometer gun and an integrated three-prong GFCI receptacle tester. This dual-instrument hardware combination evaluates surface thermal points spanning from -4°F to 752°F across standard 120V alternating current infrastructure while validating ground fault interrupter performance. Operating with a 10:1 distance-to-spot optics ratio and a sub-0.25 second response engine on an illuminated screen, it isolates structural overload heat patterns and missing ground paths inside dark utility rooms.\u003c\/p\u003e\n\u003ch3 style=\"color: #004b87;\"\u003eBest Used For:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Lug Scans:\u003c\/strong\u003e Aiming the optical targeting laser at internal panel branch connections to capture structural resistance thermal profiles up to 752°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocket Wiring Audits:\u003c\/strong\u003e Inserting the multi-LED verification module into standard 120V wall outlets to expose dual open neutral and open ground errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Duct Tracking:\u003c\/strong\u003e Pointing the pyrometer array at supply grilles, ventilation trunk registers, and line manifolds to confirm building climate balancing splits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #004b87;\"\u003eKey Performance \u0026amp; Safety Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Instrument Field Suite:\u003c\/strong\u003e Integrates a Class II laser non-contact temperature scanner with a heavy-duty three-prong circuit socket analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1 Optical Grid Resolution:\u003c\/strong\u003e Concentrates the target infrared diagnostic boundary to capture narrow thermal paths safely from a comfortable stance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Trip Tester:\u003c\/strong\u003e Receptacle block features a dedicated simulation button to trigger and test structural interrupter safety hardware components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Emissivity Standard:\u003c\/strong\u003e Pre-calibrated internal coefficient locked at 0.95 optimizes numeric accuracy across standard drywall, wood, and panel surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJobsite Hardened Armor:\u003c\/strong\u003e Impact-resistant structural polymer body assemblies pass concrete floor deck drop validation protocols from up to 6.6 feet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #004b87;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIR1 10:1 Infrared Thermometer with Targeting Laser\u003c\/li\u003e\n\u003cli\u003eRT210 GFCI Receptacle Tester\u003c\/li\u003e\n\u003cli\u003eCustom Protective Carrying Pouch\u003c\/li\u003e\n\u003cli\u003e9V Alkaline Battery\u003c\/li\u003e\n\u003cli\u003eUser Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"872\" height=\"490\" src=\"https:\/\/www.youtube.com\/embed\/M3mPnLfXnvg\" title=\"IR1 Infrared  Thermometer with Laser\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3 style=\"color: #004b87;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable height=\"646\" style=\"width: 52.1429%; border-collapse: collapse; border: 1px solid rgb(224, 224, 224); border-radius: 8px; overflow: hidden;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eThermal Monitored Span:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e-4° to 752° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eDistance-to-Spot Focus Ratio:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e10:1 Optic System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eStandard Thermometer Accuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e±4° F or ±2% (Above Freezing Benchmarks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eTelemetry Response Speed:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e\u0026lt; 0.25 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eSurface Emissivity Profile:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003eFixed at 0.95 Coefficient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eChassis Drop Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e6.6 Feet (2 Meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eOutlet Tester Compatibility:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003eStandard and GFCI 120V Alternating Current Sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eTargeting Laser Classification:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003eClass II Optical Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eDisplay Interface Profile:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003eBacklit Digital LCD Display Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eThermometer Body Length:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e6.01 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eThermometer Body Width:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e1.24 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eThermometer Body Height:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e4.14 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fff0f5;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 41.6816%;\"\u003e\u003cstrong\u003eThermometer Net Tool Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid rgb(224, 224, 224); width: 58.3184%;\"\u003e7.1 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; width: 41.6816%;\"\u003e\u003cstrong\u003eRegulatory Adherence Standards:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; width: 58.3184%;\"\u003eEN 61326-1:2013, EN 608251:2014, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote style=\"border-left: 5px solid #004b87; margin: 20px 0; padding: 15px; background-color: #f0f7ff; color: #004b87;\"\u003e\n\u003cstrong\u003ePro-Tip:\u003c\/strong\u003e When troubleshooting structural lines that output an error sequence on the outlet analyzer, guide the laser gun at the internal box wall screws; an elevated temperature reading indicates oxidized clamping threads under high current load.\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KLEIN TOOLS","offers":[{"title":"Default Title","offer_id":51944893612343,"sku":"IR1KIT","price":44.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2274\/5945\/files\/Klein_Tools_IR1KIT_Digital_Infrared_Thermometer_10_to_1_Laser_Temperature_Gun_with_RT210_GFCI_Receptacle_Outlet_Tester_Electrical_Diagnostic_Safety_Kit.jpg?v=1775854048","url":"https:\/\/www.1toptools.com\/products\/klein-tools-ir1kit-digital-infrared-thermometer-10-to-1-laser-temperature-gun-with-rt210-gfci-receptacle-outlet-tester-electrical-diagnostic-safety-kit","provider":"1 Top Tools","version":"1.0","type":"link"}